Overview

Designed with the inspector in mind

The SG NDT Cushion probes are an excellent choice for inspectors seeking both comfort and technical performance. They are specifically designed for inspecting smooth surfaces, clean welds, pipes, or semi-flat to flat structures with or without an encoder. These probes are ideal for inspecting surfaces with low-radius curves through to flat surfaces. They are durable, easy to manage, and have been designed with the inspector in mind.

The PAD-P-054-HR probe is a high-resolution inspection probe with a wear-resistant Kevlar cushioned face that can conform to gentle geometry changes. These probes have been field-proven as an excellent choice for a range of inspection requirements.
The Cushioned probe can be customized to meet specific requirements upon request, making it the ultimate tool for surface Eddy Current Array examination.

Interchangeability
The cushioned array is easily detached from the cable and multiplexer (MUX) assembly and replaced using a single tool. This means that the array can be quickly and easily replaced by other similar arrays with a different coverage, resolution or topology.

Specifications

PAD-P-054-HR Specifications

Technology

PCB Coils

Frequency Range

100kHz – 800kHz

Coil OD

3.5mm

Coil Quantity

2 Rows of 32 Intertwined
Coils (total 64)

Probe Coverage

54mm

Topology

Short Single Driver

Channels

31 Axial, 31 Transverses

(total 62)

Resolution

1.75mm Axial, 1.75mm
Transverse

Curve Radius

> 50mm

Typical Detectable Defect

> 0.5mm

Cable Length

3m Standard

Maximum Lift-Off

1.25mm

Are you interested in this product?

Our technical team is ready to answer you.

Contact Us
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.